ATR 20-slot Forced Air Conduction Cooled

ATR 20-slot Forced Air Conduction Cooled

Hybricon ProductThis Hybricon ruggedized ATR solution is a forced air conduction-cooled ATR for ground applications, with a rugged top load 6U brazed 20-slot conduction cooled card cage, folded fin heat sinks in chassis sidewalls, an 20-slot custom RF feedthrough backplane, and 800 W MIL-STD-704F conduction-cooled power supply with 28VDC input.

The chassis is cooled by 2 internal high performance MIL type fans, and the conduction cooled payload is in a sealed internal area offering protection against foreign matter. This ATR enclosure has a top access panel with captive hardware for access to the conduction cooled payload.

The front panel includes provisions for rugged I/O connectors, including signal type and RF type connectors. This rugged ATR chassis could be adapted for different applications, with VPX, OpenVPX, VXS, VME64x, CompactPCI, or hybrid type backplanes. The chassis also supports rugged environmental levels of MIL-STD-810F for shock and vibration as well as MIL-STD-461 for EMI. Different types of power input can also be accomodated, as well as different levels of payload power dissipation and/or altitude.

We specialize in providing chassis solutions, including rugged ATR solutions. Please browse our website for a sampling of other ATR chassis solutions that we have developed for specific customer applications, ATR chassis support 3U modules or 6U modules, with standard or custom backplanes, custom system monitoring, and payload integration.

Specifications

  • Description: Forced Air Conduction Cooled ATR Chassis. Top load 6U dip brazed card cage.
  • Size: 16" wide x 12" tall x 20.28" deep
  • Slot Count: 20 Slots
  • Supported Bus Structures: Custom RF feedthrough type backplane
  • Cooling: Forced air conduction cooled with front to rear air flow over folded fin stock
  • Power Supply: 28 VDC MIL-STD-704F Input. 800 Watt conduction cooled power supply